Skip to content
substralisSign inRequest access

Methodology

How Substralis reads the grid.

A handful of rules decide what appears on the map and what doesn't, then each market is read in its own terms. Every source chip in Substralis links to the section here that explains it.

Only published figures

Every figure comes from a grid operator, a regulator or an official register. We don't model, interpolate, smooth or fill gaps. If Statnett publishes no headroom for a station, the station has no headroom figure in Substralis.

Missing is not zero

A figure that isn't published is drawn as not published: dark on the map, “not published” in a table. It never becomes 0, “free” or an average of its neighbours. Where an operator publishes zero or less, we show exactly that. A fact type a market publishes but Substralis hasn't loaded yet is marked “not loaded yet”, never shown as empty.

  • Room published
  • Queue, no room published
  • Operator says full
  • Nothing published

Every figure keeps its source

Each value is stored as a claim: the source, the publisher's own date for it, and a fingerprint of the published content. Reading an unchanged source again creates no new claim, so a change in Substralis means a change at the source.

The small chip next to a figure names its source. Click it to see who published the figure, under what licence, how often we read it and when we last did, and a link to its section here; the sources page lists them all.

Units stay as published

MVA stays MVA and is never ranked against MW. A forecast stays a forecast, with its year and scenario. A status (“limited”, “short”) is never turned into a number. Demand and production are listed side by side and never added together. National queue totals aren't shown, because the same project can appear in more than one register.

What kind of figure

A room figure is one of five kinds, and the app names the kind next to the figure. Only the first is room today.

Room todayThe operator publishes how much can connect now, as MW or MVA, for new demand or new production.
A forward bandThe operator states room from a later year (“from 2029”), as Vattenfall, Fingrid and the German transmission operators do. It is not room today, and a station full today keeps its status.
A scenario forecastThe operator forecasts headroom for one year under a named scenario (ESB's, SPEN's and Electricity North West's network plans). It is a forecast for that year, not a start date; Substralis reads the publisher's central scenario and names it.
A yearly figureThe operator states one figure for each year (Fingrid's Verkkokiikari). Even this year's figure carries its year, and the station lists what each later year holds.
A conditional bandA forward band that holds only on the operator's stated condition, such as new switchgear bays being built (50Hertz). The condition is shown with the figure.

What a date means

A figure's date is the publisher's own date for it (“published”). Two sources give none: WattApp stamps a figure with the moment it serves it, so its date is the day we first read the figure unchanged (“read on”); NVE's PlanNett gives no publication date, so a study carries the day we first saw it (“first seen”). The date we fetched a source is never shown as its publication date.

Reading a queue

A connection case is waiting until the register states a reservation or an order; then it is reserved (in Norway, reserved in today's grid or in the planned grid). Waiting and reserved are two stages and are never added into one “queued” figure. Each case stays on its own side: demand, production, or, where the register states neither, unstated. A case that publishes no MW is counted, but its MW stays unknown.

A case that disappears from a register is listed as having left it, dated by our read, and kept apart from new cases.

  • Reserved
  • Waiting in the queue
  • Production

The chain above each substation

Room at a distribution substation means little if the transmission station above it is full or has a long queue. Substralis links each substation to the station it depends on, and says how the link is known:

PublishedThe grid operator states the parent, as Norway's distribution companies do in WattApp .
DocumentedA grid study, concession or operator page names it, or the documents let us follow it. The document is cited.
TracedFollowed along the operator's own line register (or, where there is none, OpenStreetMap's power lines) to a transmission station.
NearestThe closest transmission station, used only when nothing better exists: no source names it, so it is not confirmed. Drawn dotted everywhere.
PossibleWhere a check of traced links in a market found too few that held up, a traced station is shown only as a possible upstream station, never as the parent, and nothing is counted against it.

A link is only as strong as its weakest step, and is labelled that way. A long queue upstream is shown next to a substation's room. It is never subtracted from it: operators don't publish how the two interact.

Grid documents

Some figures come from documents rather than feeds: area plans, market analyses, grid studies and licensing decisions . Each keeps its document's title, publisher and date, and links to it. A plan's forward figure is the plan, not a commitment, and a document states the grid as it stood when it was written.

Tariffs

Grid tariffs are shown as each company or regulator publishes them, in their own currency and unit, excluding taxes where the publisher does . Time-of-use tariffs are shown as their published range. Tariffs from different markets are never compared as if they were one price.

The grid and the plants

Lines, stations and plants are drawn from official registers where they exist: in Norway, NVE's grid register and hydropower database . Elsewhere, and for substation outlines everywhere, they come from OpenStreetMap . No capacity or queue figure comes from these layers; they show where the grid is, not how much room it has.

Freshness is visible

Each source is read on its own timetable, at least four hours apart. A source that stops answering is flagged on the status page, not silently carried forward.

A source chip turns amber, and reads “stale”, when its figure is older than the source's own timetable would suggest (a year, for a source that publishes when it chooses). The figure is still the one published; stale says the publisher has not refreshed it, not that it is wrong.

Data centres

Data centres are gathered from registers, planning records, company statements and news. Projects change often, and some can't be confirmed. Each site shows where it comes from and how sure we are. A data centre on this map is not a grid connection and says nothing about room at a station. The layer is off by default and is a lead list, in preview until a second reader has checked a sample of it.

A site is a place where a data centre is, or is planned: a campus or a building, with its operator, its size as stated and how far along it is. It is never a queue case, a station or a capacity figure. Where the source gives no address, the site is placed on its municipality; sites on the same point are spread round it so each can be picked, and its dossier says so.

How far along it is, on one ladder, each step with the date it was stated or last checked:

  • Announced: the company says it will build here.
  • Applied: an application, environmental assessment or zoning case is filed.
  • Permitted: consent, zoning or concession granted.
  • Under construction and Operating.
  • Paused, Cancelled and Decommissioned. Ended sites are left off the map unless you pick them in the layer's filter.
  • A site whose status no source states reads “Status not published”. Rumoured sites (news only) are not on the map.

How sure we are is a second, separate axis: an official record (a register, a regulator or a municipality), a company statement (its own page or press release), reported (news, a trade association's list) or inferred. Directory listings are never used. Until the second-reader check passes, sites from research keep their status mark inside a dotted frame and are marked unverified: how sure we are never hides how far along a site is.

Size keeps its basis: operating IT load, planned IT load, or the figure “as stated” when the source does not say which. The three are never added together, and a site with no stated figure has no number, never zero. On the map a stated figure is a frame round the mark, sized by it, its line saying the basis (solid IT load, dashed planned, dotted as stated); no figure, no frame. Every site is its own mark at every zoom. Where marks sit on one another, the map shows how many share the place and a click lists them, as it does for stations; their megawatts are never added up.

Sites and grid cases meet on organisation numbers, never on names alone. A case links to a site when the case's own legal entity operates it (register), or when the case's company belongs to the site's company group and the station is the one nearest the site (matched by company and distance). When a case fits several sites, every candidate is shown and marked; none is picked. A case with no registered company is never linked. Queue megawatts stay on the case.

Competing demand on a station shows data-centre cases in the queue by stage and company group, data-centre sites nearby that have no grid case, and every case by sector. It sits beside the published room and is never subtracted from it; demand and production are never added.

Planning and permit records are read straight from their registers: Ireland's national planning applications, France's projects in environmental assessment, the Dutch official notices of environmental permits, and Great Britain's register of nationally significant projects. A record sets a site's status and dates it: an application or draft decision is applied, a grant is permitted, a refusal or withdrawal is cancelled. A permission once granted stands: a later application at the same site that is refused or still pending does not undo it. Records about equipment at an existing data centre (a generator, a battery, a cable) are kept as its records but set no status. Records of one place (the same plot, a cited reference, the same address or project code) are one site. The applicant is kept only where the record names it; megawatts only where the record states them for the data centre.

The same project can come from a record and from research. The two are shown as possibly the same project when they sit in the same municipality or within 2 km of each other and share an organisation number or a registered company group; never by name alone.

Great Britain's large-load demand is shown as UK Power Networks publishes it, in MVA: operational and pipeline data centres per local authority, and committed demand projects of 5 MVA or more per grid supply point. UKPN aggregates and anonymises them, so they are not sites, and its large-demand list does not say which projects are data centres. A figure it does not publish reads “not published”.

Coverage. Norway, Finland, the Netherlands, Ireland, Sweden, Denmark and Great Britain from our own data-centre research (rows that cite a non-directory page; Great Britain's rows from an undisclosed map are left out), and France from its assessment records; the planning and permit records above; Finland's environmental-assessment projects; Norway's grid cases from Statnett, its operator register from Nkom, and Elenia's recommended substations in Finland. Each value opens the page it came from. Licences: each page's own for research; CC BY 4.0 (Ireland, UK Power Networks), Licence Ouverte 2.0 (France), public domain (the Dutch notices) and the Open Government Licence (the NSIP register). Finland's data-centre register and the Dutch Data Center Association state no reuse terms, so their rows stay in preview.

Changes and watches. A new site, or a status that moves between two reads, appears in the briefing with the date its source states. You can watch a site: you hear when its build status moves.

Corrections. If a site, a status or a link is wrong, write to hello@substralis.com with the site's name and the page that shows it.

Norway

The figure
Available capacity for new demand and for new production at each distribution substation, in MW, as each distribution company publishes it through WattApp. A current figure, not a forecast. Statnett publishes no headroom at its own stations, so they have no figure.
The chain
Published: each distribution company states in WattApp which Statnett station its substation hangs from. Where none is stated, the link is traced along NVE's line register or taken from a grid study, and labelled as such.
Dates
WattApp publishes no date of its own, so a WattApp figure carries the day Substralis first read it unchanged (“read on”). Statnett's cases keep the dates Statnett gives: requested, queued and reserved.
The queue
Every case in Statnett's queue with the customer, MW, sector, status and dates. A case is waiting, or reserved in today's grid or in the planned grid. Statnett publishes no queue rank.
Sources

Norway: what it publishes and lacks, with the live counts

Denmark

The figure
Available capacity at distribution and transmission stations, per direction, in MW, from the Danish capacity map; free connection bays at Energinet's stations; installed generation per municipality. Current figures.
The chain
Published for most distribution stations: the capacity map states the station above each one.
Dates
The capacity map's own edition date.
The queue
None named: Denmark publishes no applicants per station, so the queue is shown as not published, never as empty.
Sources

Denmark: how far it has come

Sweden

The figure
Vattenfall's connection windows per station: from which year new load of a given size can connect, a forward figure that keeps its year. Svenska kraftnät's capacity per county: available in 2026, and applied for, allocated and reserved through 2035, in MW.
The chain
Not published by the operators. A link shown is labelled by how it is known; the nearest transmission station is used only as a last resort and drawn dotted.
Dates
Each publisher's edition date. A forward band keeps the year it refers to.
The queue
None named: applicant identity is confidential in Sweden. Svenska kraftnät's statistics count cases, and are shown as counts.
Sources

Sweden: how far it has come

Finland

The figure
Free capacity per distribution substation from Elenia, Helen, Caruna and regional companies, in MW; Fingrid's connection capacity per main-grid point and year, a forward figure that keeps its year.
The chain
Not published: which Fingrid point a distribution station depends on is not stated. A link shown is labelled by method.
Dates
Each company's edition date; Fingrid's figures keep the year they refer to.
The queue
None named.
Sources

Finland: how far it has come

Great Britain

The figure
Demand headroom at primary and bulk supply points, from each distribution operator's capacity map, in MW or MVA as the operator publishes it. Figures in different units are never ranked together; each operator's method is its own.
The chain
Published: the grid supply point above each primary comes from the operators' long-term development statements and NESO's register of grid supply points.
Dates
Each operator's edition date.
The queue
Connection registers from NESO and the distribution operators: project, MW and status. Most name no customer. A register row is placed at a station only where the match is confident, and says so.
Sources

Great Britain: how far it has come

Netherlands

The figure
A status per feeding area for new offtake (available, limited or short) and the number of requests waiting. No MW: a status is never turned into a figure, and areas are listed apart from stations with MW.
The chain
Published for most stations by the grid operators' shared register.
Dates
The capacity map's edition date.
The queue
The count of requests waiting per area, as published; no applicants are named.
Sources

Netherlands: how far it has come

Germany

The figure
Free connection capacity per transmission station and year, from 50Hertz, Amprion and TransnetBW. These bands start in 2029 and always keep their year: they are never shown as capacity today.
The chain
The bands are published at transmission stations; no distribution station is linked below them.
Dates
Each operator's edition date; each band keeps its year.
The queue
None named.
Sources

Germany: how far it has come

Ireland

The figure
Available capacity at every ESB Networks node, in MVA as ESB publishes it. MVA stays MVA and is never ranked against MW. A node ESB marks as limited by the transmission grid reads “constrained upstream”.
The chain
Published: ESB Networks states the station above almost every node.
Dates
ESB Networks' edition date.
The queue
EirGrid's and SONI's connection queues by connection point.
Sources

Ireland: how far it has come

France

The figure
RTE's offtake capacity per consumption zone (offered, allocated and residual, with works dates), and Caparéseau's injection capacity per substation, which is a figure for production, not demand.
The chain
Zones are listed, not drawn: RTE publishes no zone boundaries, and no position is invented for them.
Dates
Each publisher's edition date; works dates as RTE states them.
The queue
Queue totals by department and region from Enedis and ODRE; no applicants are named.
Sources

France: how far it has come

What we don't do

We don't invent queue positions an operator doesn't publish, we don't guess customer identities beyond what is registered, and we don't sell data. A published capacity figure is the operator's own disclosure, not an offer: connections are offered only by the grid operator, through its own process.